GEYA New Arrival GPS6-VA5 2P 80A AC220V 40-70Hz Auto Reconnect Adjustable Protector
Smart voltage/current protection with auto-recovery for unstable grid lines.
View Specifications →
Smart voltage/current protection with auto-recovery for unstable grid lines.
View Specifications →
Real-time energy metering with App-based over/under voltage trips.
View Specifications →
Heavy-duty lightning impulse protection with remote alarm signaling contact.
View Specifications →
Combined residual current and short-circuit protection for distribution boxes.
View Specifications →
High sensitivity electro-magnetic leakage breaker tailored for industrial safety.
View Specifications →
10 functional modes for precision timing sequence control in panel boards.
View Specifications →
Dedicated DC MOV technology engineered for solar combiners and PV inverters.
View Specifications →
Heavy-duty 16A switching capacity with dual SPDT contact configurations.
View Specifications →Indonesia’s transition toward renewable energy is accelerating rapidly under the Ministry of Energy and Mineral Resources (MEMR/ESDM) policies and PLN’s (Perusahaan Listrik Negara) Electricity Supply Business Plan (RUPTL 2021–2030). As commercial rooftop solar (C&I), utility-scale solar farms (PLTS), and off-grid islanded microgrids multiply across Java, Sumatra, Sulawesi, and Kalimantan, solar asset owners face a severe environmental hazard: Indonesia exhibits one of the highest keraunic levels (thunderstorm activity) in the world.
Regions such as Bogor, West Java, record over 200 thunderstorm days per year, with average cloud-to-ground (CG) lightning flash densities exceeding 12 to 18 strokes per square kilometer annually. In photovoltaic (PV) array installations, direct strikes and indirect induced switching surges generate steep transient overvoltages ($8/20\mu s$ and $10/350\mu s$ wave impulses). Without robust, tropical-grade DC Surge Protection Devices (DC SPDs), these transient surges penetrate solar string boxes, bypass standard DC fuses, and destroy expensive central or string inverters, causing millions of IDR in equipment damage and revenue loss.
A common mistake made by local electrical contractors in Southeast Asia is substituting cheaper AC surge arresters into DC photovoltaic circuits. Direct Current (DC) lacks a natural zero-crossing point. When a Metal Oxide Varistor (MOV) inside an AC arrester degrades due to equatorial heat and repeated impulse stress, the resulting DC arc will not extinguish naturally. This leads to continuous thermal runaway, melting terminal blocks, and presenting a severe fire risk inside string combiner boxes.
China’s leading DC SPD manufacturing technology—represented by Zhejiang Henergy Electrical Co., Ltd. (GEYA)—utilizes specialized Y-shaped MOV circuit topologies, integrated thermal disconnectors (TDR), and dynamic arc-extinguishing chambers designed explicitly for DC operating voltages up to 1000VDC and 1500VDC. This ensures that even under permanent MOV failure, the device safely disconnects without sustaining a continuous DC arc.
Dual thermal disconnector technology combined with rotary mechanical barriers quenches high-voltage DC arcs within milliseconds.
Encapsulated MOV modules protected against >90% RH moisture ingress, salt mist, and ambient temperatures exceeding 45°C.
Integrated dry-contact signal terminals (NC/NO) for remote status monitoring via SCADA, IoT gateways, or Tuya smart platforms.
Indonesia’s unique geographical layout—spanning over 17,000 islands with varied microclimates—demands specialized surge protection strategies tailored to specific installation environments:
Locations: Cikarang, Karawang, MM2100 Industrial Town, Surabaya, Tangerang.
Large metal deck roofs on manufacturing plants act as magnetic induction loops during electrical storms. GEYA Type 2 DC SPDs (GSP10-C40PV) installed inside combiner boxes prevent induced surge currents from traveling down long DC cable runs to string inverters, maintaining grid compliance under MEMR regulations.
Locations: Cirata Reservoir (West Java), Karangkates, Saguling.
Water bodies increase ambient humidity and risk surface flashovers. Our IP65-rated string protection modules incorporate specialized zinc oxide varistors with low leakage current characteristics ($I_{pe} < 20\mu A$), resisting dielectric insulation degradation in aquatic solar setups.
Locations: Maluku, Nusa Tenggara Timur (NTT), Papua, Outer Island Towers.
Remote diesel-solar hybrid stations and 4G/5G telecom towers on mountain ridges experience high direct-lightning frequency. Combining GEYA Type 1+2 Heavy-Duty SPDs with GPS6 Auto-Reconnect Protectors guarantees zero system downtime and eliminates expensive maintenance trips to unstaffed sites.
Selecting the correct Surge Protection Device requires matching the system DC open-circuit voltage ($U_{ocstc}$), surge discharge capacity ($I_n / I_{max}$), and protection level ($U_p$) against local PLN grid standards and IEC 61643-31 parameters.
| Model Series | System Type | Max Continuous Operating Voltage ($U_{cpv}$) | Nominal Discharge Current ($I_n$) | Max Discharge Current ($I_{max}$) | Voltage Protection Level ($U_p$) | Response Time ($\tau_A$) |
|---|---|---|---|---|---|---|
| GSP10-C40PV (600V) | 2P DC PV System | 600 VDC | 20 kA ($8/20\mu s$) | 40 kA ($8/20\mu s$) | $\le 2.5\text{ kV}$ | $< 25\text{ ns}$ |
| GSP10-C40PV (800V) | 2P DC PV System | 800 VDC | 20 kA ($8/20\mu s$) | 40 kA ($8/20\mu s$) | $\le 3.0\text{ kV}$ | $< 25\text{ ns}$ |
| GSP10-C40PV (1000V) | 2P/3P DC PV System | 1000 VDC | 20 kA ($8/20\mu s$) | 40 kA ($8/20\mu s$) | $\le 3.8\text{ kV}$ | $< 25\text{ ns}$ |
| GSP10-BC12.5 (AC) | Single/3-Phase AC | 385 VAC / 275 VAC | 25 kA ($8/20\mu s$) | 40 kA / $I_{imp}=12.5\text{kA}$ | $\le 1.5\text{ kV}$ | $< 25\text{ ns}$ |
| GPS6-VA5 Protector | 1P+N AC Distribution | AC 220V (40-70Hz) | Rated Current: 80A | Overvoltage: 230-300V | Undervoltage: 140-210V | $< 0.1\text{ s}$ |
Established in February 2007 in Yueqing, Wenzhou—China’s world-renowned low-voltage electrical apparatus hub—Zhejiang Henergy Electrical Co., Ltd. (operating globally under the premier GEYA brand) brings over 18 years of specialized manufacturing experience to the Indonesian electrical market. Verified onsite by independent inspection authority SGS Group, our state-of-the-art 10,000 m² factory houses more than 10 automated assembly lines dedicated to low-voltage power protection components.
Every batch of MOV varistors undergoes 100% incoming thermal tolerance testing and $8/20\mu s$ surge impulse calibration. Our ISO 9001 certified quality control process eliminates hidden defects before shipment.
GEYA products hold comprehensive global approvals including CB, CE, SAA, UL, VDE, and CCEE certificates. Full compliance with IEC 61643-31 and IEC 60898 standards guarantees smooth Indonesian customs clearance at Tanjung Priok and Tanjung Perak ports.
We provide customized front-panel logo laser printing, customized voltage setpoints, localized packaging design, and low MOQs starting from just 10–50 pieces per model for Indonesian wholesalers and panel builders.
Contact our senior application engineers to receive technical datasheets, certified test reports, sample kits, and factory-direct wholesale pricing tailored for the Indonesian market.
Direct Factory Support | Fast 24-Hour Inquiry Response | SGS Onsite Verified Factory