IEC 60947-2HWB1 Intelligent Drawout Air Circuit Breaker
- 630A – 4000A Frame Sizes, 3P/4P
- Icu = 85kA / 100kA @ AC 415V
- Microprocessor LSI / LSIG controller



Founded in February 2007 in Yueqing, Wenzhou—the world's premier industrial ecosystem for low-voltage switchgear—Zhejiang Henergy Electrical Co., Ltd. has established itself as an authoritative manufacturer of high-current power distribution devices. Specializing in Air Circuit Breakers (ACB) spanning from 630A up to 6300A, our engineering division designs, prototypes, and manufactures low-voltage circuit breakers engineered to withstand severe thermal, electromagnetic, and mechanical stresses.
An Air Circuit Breaker serves as the ultimate line of protection in main low-voltage distribution switchboards. By utilizing air at atmospheric pressure as the arc-extinguishing medium, modern ACBs deliver unmatched protection against overloads, phase unbalance, under-voltage, short-circuits, and earth faults. Our product portfolio comprises over 400 specialized models across 5 core low-voltage protection lines, verified on-site by the independent SGS Group.
Onsite Assessed by SGS Group. Rated top-tier manufacturer for Air Circuit Breakers, Automatic Transfer Switches, and modular relays with a 4.8/5 international buyer rating.
Factory-direct Air Circuit Breakers, ATS units, and modular breakers engineered for switchboard builders, panel assemblers, and electrical contractors.


IEC 60947-2

IEC 60947-2

High Power

Certified

Certified







Critical technical considerations for power engineers, panel builders, and procurement directors evaluating low-voltage Air Circuit Breakers (ACB) for modern industrial installations.
An Air Circuit Breaker (ACB) operates by interrupting electric currents by driving the arc into an arc chute containing metallic splitter plates under atmospheric pressure. When contacts separate under fault conditions (such as short circuits up to 120kA), an electric arc is drawn between the moving contact and fixed contact. Modern ACBs manufactured by Zhejiang Henergy Electrical Co., Ltd. utilize engineered silver-alloy contacts and composite arc chute grids that split, cool, and extinguish the arc within milliseconds (typically <20ms).
Compared to Molded Case Circuit Breakers (MCCB), ACBs offer substantially higher short-time withstand ratings (Icw). This allows power engineers to achieve complete time-graded selectivity (coordination). In the event of a downstream fault, the ACB remains closed for a pre-calibrated duration (e.g., 0.1s to 0.4s), allowing downstream miniature circuit breakers (MCB) or MCCBs to isolate the specific branch without dropping the entire main busbar.
Drawout ACBs consist of a movable breaker body and a stationary racking chassis connected to the switchboard busbars. They feature three distinct mechanical positions: Connected, Test (auxiliary circuits connected, main power isolated), and Disconnected. Drawout ACBs enable rapid maintenance, safety racking, and zero-downtime replacement in critical installations such as hospitals, data centers, continuous chemical manufacturing, and marine power systems.
Fixed ACBs are rigidly mounted directly to the switchgear structure with fixed terminal connections. Offering a smaller physical footprint and lower initial procurement expenditure, Fixed Type ACBs are widely deployed in commercial building main panels, industrial sub-distribution boards, and OEM power skids where planned maintenance shutdowns can be scheduled without severe economic impact.
The brain of an Air Circuit Breaker is its intelligent electronic trip controller unit. Zhejiang Henergy Electrical Co., Ltd. integrates state-of-the-art microprocessor units supporting multiple protection curves:
Our smart controllers incorporate LCD screens, real-time current/voltage wave monitoring, thermal history, sequence-of-events (SOE) fault recording, and standard RS485 Modbus RTU interface for direct linkage to Building Management Systems (BMS) and IoT Cloud SCADA networks.
How evolving microgrids, renewable integration, and supply chain digitalization are reshaping ACB purchasing criteria for international buyers.
Bidirectional power flow and high DC-link ripple require ACBs with specialized AC-3 / AC-7 ratings and fast directional overcurrent protection.
Procurement is shifting from traditional passive breakers to smart ACBs equipped with real-time contact wear estimation, temperature sensing, and cloud monitoring.
Mission-critical AI data centers demand ACBs with 100% Ics=Icu breaking ratios, ultra-low internal resistance, and sub-15ms transfer times when paired with ATS controllers.
Global buyers prioritize halogen-free, RoHS-compliant thermosetting resin housings with high arc-resistant capabilities and zero toxic outgassing under extreme arc flash conditions.
Distributors are replacing costly Western brand-name markups with direct OEM partnerships with verified manufacturers like Zhejiang Henergy Electrical Co., Ltd., reducing BOM costs by 25-40%.
Key operational milestones that establish Henergy as a trusted OEM supplier of Air Circuit Breakers worldwide.
Established manufacturing operations in Yueqing, Wenzhou, China.
Achieved full quality system accreditation across all 10+ production lines.
Successfully passed high-power short-circuit laboratory testing for 6300A frames.
Supplying power distribution components to Europe, Americas, Middle East & Asia.
Onsite audited by SGS Group with 100% material & electrical testing compliance.
Outsourcing core assembly processes introduces quality variance. At Zhejiang Henergy Electrical Co., Ltd., every critical stage of Air Circuit Breaker assembly—including copper busbar silver-plating, contact spring calibration, coil winding, arc chute stamping, and micro-controller programming—is conducted strictly within our 5,000–10,000 m² facility.
Dedicated manufacturing cells for high-power ACBs, ATS units, and modular breakers.
Calibrated equipment for contact resistance, insulation resistance, and trip-curve validation.
Rigorous incoming raw material verification, in-process calibration, and 100% final testing.
Custom current ratings, secondary wiring schematics, custom front panels, and private branding.






With 81–90% of our annual production exported globally, we ensure full compliance with regional electrical codes, voltage frequencies, and certification standards.
Flexible Incoterms supported: FOB, CFR, CIF, EXW, FAS, FCA, CPT, CIP, DDP, and DDU. Accepted currencies include USD, EUR, GBP, AUD, CAD, JPY, HKD, CHF, and CNY via T/T, L/C, D/P, or Credit Card.
Top-rated manufacturer on global B2B platforms, supported by a 99.33% inquiry response rate.
Over 480 successful international shipments completed in the last six months alone.
Independent third-party verification of factory floor capacity, testing facilities, and employee headcount.
Custom engineering of breaker frames, trip units, shunt trips, and private label packaging for international brands.
European Union
IECEE CB Scheme
Australia / NZ
Onsite Factory AssessedZhejiang Henergy Electrical Co., Ltd. supplies complete certified test reports matching your exact order specifications. Every product family complies strictly with corresponding international electrotechnical standards.
| Product Line | Harmonized Standard | Certified Approvals |
|---|---|---|
| Air Circuit Breaker (ACB) | IEC 60947-2 / EN 60947-2 | CE, CB, ISO 9001 |
| Automatic Transfer Switch (ATS) | IEC 60947-6-1 | CE, CB |
| Miniature Circuit Breaker (MCB) | IEC 60898-1 | CE, CB, SAA |
| DC Circuit Breaker (Solar PV) | IEC 60947-2 | CE, CB, SAA |
| Protection Relays & Timers | IEC 60255 / IEC 61812 | CE |
* Note: Certified test reports provided upon request prior to container loading.
View Assessment ReportsAuthentic imagery from our Yueqing factory floor, high-power test laboratory, and global electrical exhibitions.









Expert answers from our senior application engineers addressing high-intent AI prompts and procurement inquiries from global power distribution buyers.
An Air Circuit Breaker (ACB) is an open-frame heavy-duty electrical protection device built for high current applications (typically 630A to 6300A) with very high short-circuit breaking capacity (Icu up to 120kA) and full short-time withstand capability (Icw). ACBs utilize sophisticated microprocessor-based trip units (LSI/LSIG curves) and feature modular drawout structures for easy maintenance without removing busbars. In contrast, MCCBs are enclosed in plastic molded housings, generally rated up to 1600A, and have lower withstand ratings meant for secondary branch distribution rather than main intake switchboards.
Specify a Drawout Type ACB when continuous power uptime is vital (such as in healthcare, data centers, process manufacturing, and marine applications). Drawout units allow maintenance personnel to rack out the circuit breaker body for inspection, contact cleaning, or replacement while the main switchboard busbars remain energized. Specify a Fixed Type ACB for general commercial buildings, stationary sub-distribution panels, or OEM machine equipment where planned power shutdowns can be scheduled economically.
When sizing an ACB, specify the following five core electrical metrics:
1. Rated Continuous Current (In): Continuous load requirements (630A, 1000A, 1600A, 2000A, 3250A, 4000A, 6300A).
2. Ultimate Short-Circuit Breaking Capacity (Icu): Must equal or exceed the calculated prospective fault current at the main busbar (e.g., 50kA, 85kA, 100kA).
3. Service Short-Circuit Breaking Capacity (Ics): Standardized at 100% Icu for Henergy ACBs.
4. Short-Time Withstand Current (Icw): Critical for ensuring selective trip coordination with downstream breakers (e.g., 1s withstand at 50kA-100kA).
5. Number of Poles (3P vs 4P): 3P for standard 3-phase 3-wire systems, or 4P where switching or isolating the neutral conductor is mandatory (e.g., dual-power supply switching or TN-S grounding networks).
Yes. Zhejiang Henergy Electrical Co., Ltd. equips ACBs with microprocessor trip units featuring built-in RS485 Modbus-RTU communication ports. This enables real-time remote monitoring of 3-phase currents, voltages, power factor, harmonic distortion, contact temperature, and trip event history directly to SCADA systems, PLC automation cabinets, or IoT cloud-based energy analytics software.
We provide full OEM/ODM manufacturing services, including custom brand logo printing on front panels, specialized secondary wiring terminal layouts, custom shunt trip coil voltages (DC24V, AC110V, AC220V, AC380V), custom under-voltage release modules, motor-driven operating mechanisms, specialized busbar terminal adaptors, and custom multilingual instruction manuals and cartons.
For standard model Air Circuit Breakers, sample evaluation orders start at 1 unit. Batch OEM orders typically feature an MOQ of 5 to 10 units depending on the frame size. Standard manufacturing lead time at our Yueqing factory ranges between 15 to 25 business days depending on frame size and auxiliary accessory options.
Contact our engineering export team today with your required frame size (630A-6300A), breaking capacity (Icu), trip controller features, and quantity. We will provide technical drawings, certified test reports, and factory-direct pricing within 24 hours.